12
Installation Of CO
2
Tank Fasterner (see illustriation below)
Before install he CO
2
Tank to it’s position, make sure to attached the Regulator and the CO2 red
hose first, securely tightened. The CO2 tank cushion should also be sticked to the bottom of the
tank.
First buckle the CO2 tank fasterner to one end of the inner lock piece at the right inner side.
Then put the CO2 tank in its position for safety lock.
Pull tight the fasterner and buckle the other end into the lock piece.
Check and make sure the buckle are tight and secure.
Installation of the Keg Coupler
Insert the keg coupler provided into the locking neck of the beer keg
and turn it clockwise to lock into position, making sure the keg coupler
is in the closed position. (See Figure 3)
Figure 3
Installation Of The Beer Tower
Remove the top plug by twisting and pulling out, saving it for later use if you decide to convert unit
to an all refrigerator unit.
For tight connection, you may need the Mylar washer provided, put it on the plastic socket which
accomodate the beer tower.
Unravel the beer line (clear hose) from the tower and insert the beer line and wing nut through the
uncovered hole on top.
Lock the beer tower assembly to the top and make sure to position the beer faucet so it is aligned
with the cabinet front (6 o’clock position). You accomplish this by aligning the bottom of the beer
tower to the 3 grooves on the top cabinet and tighten by hand clockwise to properly lock.
Installation Of The Keg Coupler
Insert the keg coupler provided into the locking neck of the beer keg and turn it clockwise to lock
into position, making sure the keg coupler is in the closed position. (See Figure 7)
Installation Of The CO2 Air Line Hose
Attach the end of the air line(red) hose provided to the hose connection on the keg coupler.
Secure hose by using the connector and make sure there are no leaks.