0

Out of 0 Ratings

Owner's of the Avanti Beverage Dispenser BD7000 gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 36
 
10
Reversing the Door Swing of Your Appliance
This appliance has the capability of the door opening from either the left or right side. The unit is
delivered to you with the door opening from the left side. Should you desire to reverse the opening
direction, please call service for reversal instructions.
INSTALLING AND ASSEMBLING YOUR APPLIANCE
Casters with Brake (OPTIONAL ACCESSORIES) Installation
THESE CASTERS ARE NOT INCLUDED WITH YOUR UNIT.
Casters can be ordered from the Avanti Parts and Service Department at 1-800-220-5570 or by
using the Accessory Order Form included with this manual.
Install the four casters with lock provided into the unit’s bottom (four screw holes pre-supplied).
Figure (I) before installation. Figure (II) is the final version.
Figure (I): Before Installation Figure (II): After Installation
WARNING
CO
2
GAS CAN BE DANGEROUS
WARNING: CO
2
cylinders contain high-pressure compressed gas which can be hazardous if not
handled properly. Make sure you READ and UNDERSTAND the following procedures for CO
2
cylinders BEFORE INSTALLATION.
1. ALWAYS connect the CO
2
cylinder to a regulator. Failure to do so could result in explosion
with possible death or injury when the cylinder valve is opened.
2. NEVER connect the CO
2
cylinder directly to the product container.
3. ALWAYS follow correct procedures when cylinders are changed.
4. ALWAYS secure the cylinder in an upright position.
5. NEVER drop or throw a CO
2
cylinder.
6. ALWAYS keep a CO
2
cylinder away from heat. Store extra cylinders in a cool place
(preferably 70°F). Securely fasten with a chain in an upright position when storing.
7. ALWAYS ventilate and leave the area immediately if CO
2
leakage has occurred.
8. ALWAYS check the D.O.T. test date on the cylinder neck before installation. If over five (5)
years, do not use, return cylinder to gas supplier.
9. NEVER connect a product container unless there are two (2) safety’s in the pressure system:
a. One at or on the CO
2
regulator
b. One at or on the product coupler or in the pressure gas line.